Date |
Text |
2021-02-16 17:15:21 | DENIED |
| |
| PERMIT 19020199 - UNDERGROUND FIBER FLAGLER AND FERN |
| MCIMETRO PROJECT #1806CQB.1 1/2021 RESUBMITTAL |
| |
| PROVIDE WRITTEN RESPONSE TO COMMENTS. |
| |
| THE FOLLOWING ITEMS NEED TO BE ADDRESSED OR THE PERMIT |
| WILL NOT BE APPROVED. |
| |
| 1) ENGINEERING PLAN - THE REVISED BORE LOCATION |
| INCLUDES A CROSSING OF FERN STREET WHICH INCLUDES A |
| PROPOSED OPEN CUT, THREE FEET DEEP, LEADING TO HANDHOLE |
| 8+95. THE LOCATION OF THE PROPOSED OPEN CUT IS AN AREA |
| THAT INCLUDES BIOSWALE PITS THAT ARE SURROUNDED BY |
| STRUCTURAL SOIL. THE STRUCTURAL SOIL HAS EXACTING |
| INSTALLATION STANDARDS AND MAY NOT BE DISTURBED. YOU |
| NEED TO GET THE AS BUILT DRAWINGS SHOWING THE LIMITS OF |
| THE STRUCTURAL SOIL AND DESIGN YOUR INSTALLATION TO |
| AVOID THE STRUCTURAL SOIL. IF THERE IS ROOM BETWEEN THE |
| TWO AREAS OF STRUCTURAL SOIL (AROUND EACH BIOSWALE TREE |
| PIT) THEN THE FERN STREET CROSSING SHOULD BE DIRECT |
| FROM HANDHOLE 8+00 TO THE NEW HANDHOLE ON THE SOUTH |
| SIDE OF THE STREET (DO NOT WRAP AROUND THE BIOSWALE |
| TREE PIT). |
| |
| PLEASE NOTE: |
| |
| THE INSTALLATION CONTRACTOR MUST CONTACT SUNSHINE 811 |
| TO VERIFY THE LOCATION OF ALL UTILITIES AND VERIFY ALL |
| DEPTHS PRIOR TO CONSTRUCTION. ALL CITY UTILITIES MUST |
| BE LOCATED BY SOFT DIG METHODS BEFORE STARTING THE |
| WORK. |
| |
| THE RIGHT-OF-WAY USE PERMIT REQUIRES YOU TO PROVIDE A |
| CERTIFICATE OF LIABILITY INSURANCE, WHICH IN ACCORDANCE |
| WITH SECTION 78-406 OF THE CITY CODE SPECIFICALLY NAMES |
| THE CITY OF WEST PALM BEACH, ITS COMMISSIONERS, |
| OFFICERS, EMPLOYEES AND AGENTS AS ADDITIONAL INSURED. |
| |
| CONTACT ERIC SCHNEIDER @ (561) 822-1446 |
| [email protected] |
| |
| |