Plan Review Notes For Permit 19020199
Permit Number 19020199
Review Stop Z
Sequence Number 4
Notes
Date Text
2021-02-16 17:15:21DENIED
  
 PERMIT 19020199 - UNDERGROUND FIBER FLAGLER AND FERN
 MCIMETRO PROJECT #1806CQB.1 1/2021 RESUBMITTAL
  
 PROVIDE WRITTEN RESPONSE TO COMMENTS.
  
 THE FOLLOWING ITEMS NEED TO BE ADDRESSED OR THE PERMIT
 WILL NOT BE APPROVED.
  
 1) ENGINEERING PLAN - THE REVISED BORE LOCATION
 INCLUDES A CROSSING OF FERN STREET WHICH INCLUDES A
 PROPOSED OPEN CUT, THREE FEET DEEP, LEADING TO HANDHOLE
 8+95. THE LOCATION OF THE PROPOSED OPEN CUT IS AN AREA
 THAT INCLUDES BIOSWALE PITS THAT ARE SURROUNDED BY
 STRUCTURAL SOIL. THE STRUCTURAL SOIL HAS EXACTING
 INSTALLATION STANDARDS AND MAY NOT BE DISTURBED. YOU
 NEED TO GET THE AS BUILT DRAWINGS SHOWING THE LIMITS OF
 THE STRUCTURAL SOIL AND DESIGN YOUR INSTALLATION TO
 AVOID THE STRUCTURAL SOIL. IF THERE IS ROOM BETWEEN THE
 TWO AREAS OF STRUCTURAL SOIL (AROUND EACH BIOSWALE TREE
 PIT) THEN THE FERN STREET CROSSING SHOULD BE DIRECT
 FROM HANDHOLE 8+00 TO THE NEW HANDHOLE ON THE SOUTH
 SIDE OF THE STREET (DO NOT WRAP AROUND THE BIOSWALE
 TREE PIT).
  
 PLEASE NOTE:
  
 THE INSTALLATION CONTRACTOR MUST CONTACT SUNSHINE 811
 TO VERIFY THE LOCATION OF ALL UTILITIES AND VERIFY ALL
 DEPTHS PRIOR TO CONSTRUCTION. ALL CITY UTILITIES MUST
 BE LOCATED BY SOFT DIG METHODS BEFORE STARTING THE
 WORK.
  
 THE RIGHT-OF-WAY USE PERMIT REQUIRES YOU TO PROVIDE A
 CERTIFICATE OF LIABILITY INSURANCE, WHICH IN ACCORDANCE
 WITH SECTION 78-406 OF THE CITY CODE SPECIFICALLY NAMES
 THE CITY OF WEST PALM BEACH, ITS COMMISSIONERS,
 OFFICERS, EMPLOYEES AND AGENTS AS ADDITIONAL INSURED.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  
  