2020-07-24 11:36:21 | PERMIT 20060481 AT&T CRAN_RTFL_PBC36_01 4 916 5TH ST |
| |
| THE PROPOSED POLE LOCATION IS IN A RESIDENTIAL AREA. IN |
| ACCORDANCE WITH SECTION 78-411(B)(2) OF THE CITY CODE, |
| WHENEVER WIRELESS FACILITIES MUST BE PLACED IN A |
| RIGHT-OF-WAY WITH RESIDENTIAL USES ON ONE OR BOTH |
| SIDES, NEITHER POLES, EQUIPMENT, ANTENNAS OR OTHER |
| STRUCTURES SHALL BE PLACED DIRECTLY IN FRONT OF A |
| RESIDENTIAL STRUCTURE. ALL WIRELESS FACILITIES SHALL BE |
| LOCATED SUCH THAT VIEWS FROM RESIDENTIAL STRUCTURES ARE |
| NOT SIGNIFICANTLY IMPAIRED. THE SITE PLAN PROVIDED WITH |
| THE APPLICATION APPEARS TO CONFLICT WITH THE LOCATIONAL |
| REQUIREMENT. ONCE THE REQUIRED SURVEY IS PROVIDED, |
| STAFF WILL BE ABLE TO VERIFY COMPLIANCE. IN THE EVENT |
| THAT THE POLE IS PROPOSED IN FRONT OF THE RESIDENCE (AS |
| INDICATED ON THE SITE PLAN), THEN THE POLE MUST BE |
| RELOCATED. STAFF SUGGESTS TO THE WEST AT THE PROPERY |
| LINE EXTENDED BETWEEN THE RESIDENCE AND THE NEIGHBORING |
| LOT. |
| |
| PLEASE SEE THE LIST BELOW FOR AN ANALYSIS OF THE |
| DEFICIENCIES IN INFORMATION REQUIRED BY SECTION 78-401 |
| OF THE CITY OF WEST PALM BEACH CODE AS PART OF THE |
| COMMUNICATION FACILITIES PLACEMENT PERMIT APPLICATION. |
| THE DEFICIENT INFORMATION MUST BE PROVIDED FOR STAFF TO |
| REVIEW THE PERMIT APPLICATION. PLEASE NOTE THAT STAFF |
| HAS ALSO INCLUDED SOME SUBSTANTIVE REVIEW COMMENTS, |
| THAT WHILE NOT RESULTING IN A DEFICIENT APPLICATION, |
| NEED TO BE ADDRESSED OR THE PERMIT WILL NOT BE |
| APPROVED. |
| |
| 1) ENGINEERING PLAN - SIGNED BY A FLORIDA REGISTERED |
| ENGINEER |
| |
| A. THE ENGINEERING PLANS DID NOT INCLUDE A SCALE. THE |
| CITY CODE REQUIRES THE PLANS TO BE DRAWN AT A 10FT, |
| 20FT, OR 40FT SCALE. PROVIDE THE PLANS AT THE REQUIRED |
| SCALE. |
| |
| B. THE SUBMITTED ENGINEERING PLAN MUST BE BASED ON THE |
| REQUIRED SURVEYS AND SHOW THE ABOVE AND BELOW GROUND |
| FEATURES. THIS INCLUDES THE TREES ALONG THE |
| RIGHT-OF-WAY. |
| |
| C. THE SIZE OF THE PROPOSED POLE BASE WITHIN THE |
| RIGHT-OF-WAY MUST BE SHOWN ON THE ENGINEERING PLAN. |
| |
| 2) REPEAT COMMENT: SURVEY OF UNDERGROUND FACILITIES - |
| THE BASE OF THE POLE IS BEING INSTALLED UNDERGROUND SO |
| THIS IS REQUIRED. |
| |
| A. THE SURVEY, PREPARED BY A FLORIDA REGISTERED |
| SURVEYOR, MUST CLEARLY SHOW THE RIGHT-OF-WAY LINE, THE |
| SIDEWALK AND THE UTILITY EASEMENT LISTED ON THE |
| ENGINEERING PLANS. |
| |
| B. ALL UNDERGROUND UTILITIES NEED TO BE PROVIDED ON THE |
| SURVEY. IF THE BORE IS PROPOSED WITHIN FIVE (5) FEET OF |
| AN EXISTING UTILITY, YOU NEED TO PROVIDE A LETTER FROM |
| THAT UTILITY THAT THE PROPOSED BORE DOES NOT INTERFERE |
| WITH THE PROVISIONS OF THEIR SERVICES. |
| |
| C. THE TREES AND THEIR ROOT ZONE NEED TO BE SHOWN. THE |
| FIBER BORE NEEDS TO BE CLEARLY SHOWN AVOIDING DAMAGE TO |
| THE TREE ROOT ZONES. |
| D. THE ENGINEERING PLAN MUST BE BASED OFF OF THIS |
| SURVEY INFORMATION. |
| |
| 3) REPEAT COMMENT: SURVEY OF ABOVEGROUND FACILITIES - A |
| NEW POLE IS BEING INSTALLED ABOVEGROUND SO THIS IS |
| REQUIRED. |
| |
| A. IDENTIFY ALL ABOVEGROUND FEATURES TO INCLUDE TREES |
| ON A SURVEY PREPARED BY A FLORIDA LICENSED SURVEYOR. |
| |
| B. IDENTIFY ALL ABOVEGROUND COMMUNICATION FACILITIES IN |
| THE AREA TO INCLUDE AN INVENTORY OF THE REGISTRANT'S |
| EXISTING FACILITIES - NO INFORMATION ON EXISTING |
| FACILITIES WAS PROVIDED. SHOW THIS INFORMATION ON THE |
| PLANS AND PROVIDE A NARRATIVE. IF THERE ARE NO |
| FACILITIES, THIS SHALL BE NOTED ON THE SURVEY. |
| |
| C. YOU ARE REQUIRED TO PROVIDE INFORMATION REGARDING |
| EXISTING UTILITY POLES (INCLUDING LIGHT POLES) WITHIN |
| 50 FEET OF YOUR PROPOSED POLE. THE POLE HEIGHT AND BASE |
| DIAMETER SHALL BE INCLUDED. THIS WILL BE USED TO VERIFY |
| IF THE PROPOSED 25 FOOT SUPPORT POLE HEIGHT COMPLIES |
| WITH THE HEIGHTS OF EXISTING UTILITY POLES. |
| |
| D. THE ENGINEERING PLAN MUST BE BASED OFF OF THIS |
| SURVEY INFORMATION. |
| |
| 4) RADIO FREQUENCY INTERFERENCE - NO INFORMATION WAS |
| PROVIDED THAT THE PROPOSED FACILITIES WILL NOT CAUSE |
| RADIO FREQUENCY INTERFERENCE WITH THE CITY'S PUBLIC |
| SAFETY COMMUNICATIONS EQUIPMENT. PROVIDE A STATEMENT |
| REGARDING RADIO FREQUENCY INTERFERENCE. |
| |
| 5) THANK YOU FOR USING A POLE STYLE THAT MEETS THE |
| CITY'S CONCEALMENT REQUIREMENTS. AT THIS LOCATION, THE |
| CITY REQUIRES THE POLE TO BE EITHER BLACK OR GREEN, NOT |
| ITS NATURAL STEEL COLOR. PLEASE SPECIFY THE COLOR YOU |
| CHOOSE TO USE ON THE PLANS. |
| |
| 6) EVIDENCE OF INSURANCE COVERAGE - YOU ARE REQUIRED TO |
| SUBMIT VERIFICATION OF INSURANCE IN ACCORDANCE WITH THE |
| PROVISIONS OF SECTION 78-406 OF THE CITY CODE OF |
| ORDINANCES. PLEASE REMEMBER THAT THE CERTIFICATE OF |
| LIABILITY INSURANCE NEEDS TO BE ISSUED TO THE APPLICANT |
| LISTED ON THE COMMUNICATIONS FACILITIES PLACEMENT |
| PERMIT APPLICATION - NEW CINGULAR WIRELESS LLC. |
| |
| 7) START OF OPERATION - AN ATTESTATION FROM THE |
| COMMUNICATIONS FACILITIES SERVICE PROVIDER THAT |
| COMMUNICATIONS SERVICES FACILITIES WILL BE INSTALLED |
| AND OPERATIONAL ON THE PROPOSED STRUCTURE NO LATER THAN |
| NINE MONTHS AFTER THE DATE THE APPLICATION IS APPROVED |
| IS REQUIRED. PROVIDE THE REQUIRED ATTESTATION. |
| |
| 8) PUBLIC UTILITY LETTERS, TELEPHONE, NATURAL GAS, |
| ELECTRIC SERVICE, AND TELEVISION CABLE - THE PUBLIC |
| UTILITY LETTERS WERE NOT PROVIDED. PROVIDE COPIES OF |
| THE PUBLIC UTILITY LETTERS FROM ANY PROVIDER WITH |
| FACILITIES SHOWN ON THE SURVEY WITHIN FIVE (5) FEET OF |
| THE POLE BASE. |
| |
| 9) ELECTRONIC FORMAT OF SUBMITTAL - THE SUBMITTAL WAS |
| NOT PROVIDED IN ELECTRONIC FORM. A COPY OF ALL OF THE |
| SUBMITTAL MATERIAL MUST BE SUBMITTED IN ELECTRONIC |
| FORMAT. |
| |
| CONTACT ERIC SCHNEIDER @ (561) 822-1446 |
| [email protected] |
| |