2019-12-13 15:57:11 | INSUFFICIENT |
| |
| PERMIT 19100100 SPRINT MI90XSQ95-F 437 IRIS ST |
| 2ND REVIEW |
| |
| PLEASE SEE THE LIST BELOW FOR AN ANALYSIS OF THE |
| DEFICIENCIES IN INFORMATION REQUIRED BY SECTION 78-401 |
| OF THE CITY OF WEST PALM BEACH CODE AS PART OF THE |
| COMMUNICATION FACILITIES PLACEMENT PERMIT APPLICATION. |
| THE DEFICIENT INFORMATION MUST BE PROVIDED FOR STAFF TO |
| REVIEW THE PERMIT APPLICATION. PLEASE NOTE THAT STAFF |
| HAS ALSO INCLUDED SOME SUBSTANTIVE REVIEW COMMENTS, |
| THAT WHILE NOT RESULTING IN A DEFICIENT APPLICATION, |
| NEED TO BE ADDRESSED OR THE PERMIT WILL NOT BE |
| APPROVED. |
| |
| 1) REPEAT COMMENT: ENGINEERING PLAN |
| |
| A. THE SUBMITTED ENGINEERING PLAN MUST BE BASED ON THE |
| REQUIRED SURVEYS. |
| |
| B. THE SIZE OF THE PROPOSED POLE BASE WITHIN THE |
| RIGHT-OF-WAY MUST BE SHOWN ON THE ENGINEERING PLAN. |
| |
| C. THERE IS A BUILDING WITH A ZERO FOOT SETBACK FROM |
| THE PROPERTY LINE APPROVED FOR THE CURRENTLY VACANT |
| SITE ABUTTING THE PROPOSED POLE LOCATION, WITH TREES |
| THAT WILL BE INSTALLED IN THE RIGHT-OF-WAY. YOUR POLE |
| MAY NOT BE INSTALLED IN THE PROPOSED LOCATION, BUT MUST |
| INSTEAD BY LOCATED AWAY FROM THE PROPERTY LINE AND IN |
| LINE WITH THE FUTURE STREET TREES. |
| |
| 2) REPEAT COMMENT: SURVEY OF UNDERGROUND FACILITIES - |
| THE BASE OF THE POLE IS BEING INSTALLED UNDERGROUND SO |
| THIS IS REQUIRED. |
| |
| A. ALL UNDERGROUND UTILITIES NEED TO BE PROVIDED ON A |
| SURVEY PREPARED BY A FLORIDA LICENSED SURVEYOR. SHEET |
| SE-1 IS NOT A SURVEY PREPARED BY A FLORIDA LICENSED |
| SURVEYOR, NOR DOES IT SHOW THE UNDERGROUND UTILITIES. |
| |
| B. THE ENGINEERING PLAN MUST BE BASED OFF OF THIS |
| SURVEY INFORMATION. |
| |
| 3) REPEAT COMMENT: SURVEY OF ABOVEGROUND FACILITIES - A |
| NEW POLE IS BEING INSTALLED ABOVEGROUND SO THIS IS |
| REQUIRED. |
| |
| A. IDENTIFY ALL ABOVEGROUND FEATURES TO INCLUDE TREES |
| ON A SURVEY PREPARED BY A FLORIDA LICENSED SURVEYOR. |
| SHEET SE-1 IS NOT A SURVEY PREPARED BY A FLORIDA |
| LICENSED SURVEYOR, NOR DOES IT SHOW THE ABOVEGROUND |
| FEATURES. |
| |
| B. IDENTIFY ALL ABOVEGROUND COMMUNICATION FACILITIES IN |
| THE AREA TO INCLUDE AN INVENTORY OF THE REGISTRANT'S |
| EXISTING FACILITIES - NO INFORMATION ON EXISTING |
| FACILITIES WAS PROVIDED. SHOW THIS INFORMATION ON THE |
| PLANS AND PROVIDE A NARRATIVE. IF THERE ARE NO |
| FACILITIES, THIS SHALL BE NOTED ON THE SURVEY. |
| |
| C. YOU ARE REQUIRED TO PROVIDE INFORMATION REGARDING |
| EXISTING UTILITY POLES (INCLUDING LIGHT POLES) WITHIN |
| 50 FEET OF YOUR PROPOSED POLE. THE POLE HEIGHT AND BASE |
| DIAMETER SHALL BE INCLUDED. PLEASE NOTE: THE SUPPORT |
| POLE INCLUDED WITH THIS APPLICATION IS 35 FEET ABOVE |
| GRADE IN HEIGHT, WHICH DOES NOT APPEAR TO COMPLY WITH |
| THE HEIGHT STANDARDS LISTED IN SECTION 78-411(G)(1) OF |
| THE CITY CODE. |
| |
| D. THE ENGINEERING PLAN MUST BE BASED OFF OF THIS |
| SURVEY INFORMATION. |
| |
| 4) REPEAT COMMENT: CONCEALMENT METHODS DESCRIPTIONS - |
| NO CONCEALMENT INFORMATION WAS PROVIDED. PLEASE NOTE |
| THAT THE PROPOSED SUPPORT POLE, INCLUDING THE ANTENNA, |
| EQUIPMENT AND METER ATTACHMENTS, DOES NOT MEET THE CITY |
| CONCEALMENT STANDARDS OUTLINED IN SECTION 78-411 OF THE |
| CITY CODE. THE POLE ELEVATION MUST INCLUDE ALL THE |
| DIMENSIONS. NOTE: THE POLE AND WIRELESS COMMUNICATION |
| EQUIPMENT MAY NOT BE TWO INSTALLATIONS, BUT MUST RATHER |
| BE ONE INTEGRATED INSTALLATION. YOU ARE NOT ATTACHING |
| EQUIPMENT TO AN EXISTING POLE AS STATED IN THE RESPONSE |
| SINCE THERE IS NO EXISTING POLE. YOU MUST SUBMIT A |
| CONCEALED DESIGN. |
| |
| 5) REPEAT COMMENT: CONSTRUCTION TIMETABLE - YOU MUST |
| PROVIDE AN ESTIMATED TIMETABLE FOR CONSTRUCTION OF THE |
| PROJECT. |
| |
| 6) REPEAT COMMENT: RESTORATION ESTIMATE - YOU MUST |
| PROVIDE A RESTORATION ESTIMATE, WHICH IS THE COST FOR |
| THE RESTORATION THAT YOU LIST ON SHEET R-1. THE NOTES |
| ON SHEET R-1 MUST BE UPDATED TO NOT REFERENCE THE CITY |
| OF FORT LAUDERDALE REQUIREMENTS. |
| |
| 7) REPEAT COMMENT: EVIDENCE OF INSURANCE COVERAGE - YOU |
| ARE REQUIRED TO SUBMIT VERIFICATION OF INSURANCE IN |
| ACCORDANCE WITH THE PROVISIONS OF SECTION 78-406 OF THE |
| CITY CODE OF ORDINANCES. |
| |
| 8) REPEAT COMMENT: START OF OPERATION - AN ATTESTATION |
| FROM THE COMMUNICATIONS FACILITIES SERVICE PROVIDER |
| THAT COMMUNICATIONS SERVICES FACILITIES WILL BE |
| INSTALLED AND OPERATIONAL ON THE PROPOSED STRUCTURE NO |
| LATER THAN NINE MONTHS AFTER THE DATE THE APPLICATION |
| IS APPROVED IS REQUIRED. PROVIDE THE REQUIRED |
| ATTESTATION. |
| |
| 9) REPEAT COMMENT: PUBLIC UTILITY LETTERS, TELEPHONE, |
| NATURAL GAS, ELECTRIC SERVICE, AND TELEVISION CABLE - |
| THE PUBLIC UTILITY LETTERS WERE NOT PROVIDED. PROVIDE |
| COPIES OF THE PUBLIC UTILITY LETTERS. |
| |
| 10) REPEAT COMMENT: PROVIDER CLARIFICATION - ON THE |
| COMMUNICATIONS FACILITIES PLACEMENT PERMIT APPLICATION, |
| YOU MARKED THAT THIS IS A PASS THROUGH PROVIDER, YET |
| YOU HAVE ALSO MARKED THAT YOU ARE A COMMUNICATION |
| SERVICES PROVIDER THAT REMITS TAXES TO THE CITY. BY |
| CITY DEFINITION, YOU CANNOT BE BOTH. IF YOU ARE A PASS |
| THROUGH PROVIDER, YOU ARE REQUIRED TO PAY AN |
| APPLICATION FEE TO THE CITY. |
| |