2013-09-30 16:07:22BUILDING PLAN REVIEW
 PERMIT: 13070610
 ADD: 720 S SAPODILLA AV- ROOFTOP
 CONT: HAYDEN PROFESSIONAL SERVICES
 TEL: (772)781-1512
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 3RD REVIEW
 DATE:9/ 30/2012
 ACTION: DENIED
  
 1) COMPLIED. PLANS BEING SUBMITTED FOR CITY REVIEW
 REQUIRES CITY PLACE STAMP OF REVIEW AND APPROVAL.
  
 2A) 3RD REVIEW. SUBMITTED IS A PRE-MANUFACTURED
 BUILDING, THIS STATE APPROVED PLAN, HAS VARIOUS OPTIONS
 AS TO VARIOUS OPTIONS TO 1 OR 2 HOUR FIRE RATINGS,
 PLEASE CIRCLE WHICH OPTION WILL BE EXERCISED IN
 BUILDING THIS UNIT.
 THE ISSUE IS THIS MODULAR BUILDING IS GOING TO BE
 LOCATED ON TOP OF AN EXISTING 5 STORY III-A FULLY
 SPRINKLERED BUILDING. THE STATE APPROVED PLAN INDICATES
 THIS TO BE A BUILDING TYPE V-B BUT WITH THE VARIOUS
 OPTIONS IT CAN BE UPGRADED TO THE REQUIREMENTS OF A
 BUILDING TYPE IIIA.
 THE ORIGINAL BUILDING BEING BUILT AS A MIXED USE
 MERCANTILE 1ST FLOOR AND R2 THE SECOND THRU 5TH FLOOR
 WHICH ALLOWED FOR 4 STORIES, IT IS FULLY SPRINKLERED
 WITH A FULL NFPA 13 SPRINKLER THAT GACE THEM A ONE
 STORY INCREASE, THE NEW MODULAR STRUCTURE WOULD ALSO BE
 REQUIRED TO BE FULLY SPRINKLERED AND A MINIMUM BUILDING
 TYPE OF IIIA.
  
 2B) WE WILL STILL NEED DOCUMENTATION THAT THIS BUILDING
 WILL BE EITHER FIRE SPRINKLERED OR MEET THE REQUIREMENT
 THROUGH AN ALTERNATE METHOD.
  
 3) COMPLIED. 2ND REQUEST.SHEET S2 DETAIL # 5 INDICATES
 A SPECIAL PLATE DETAIL OF THE STEEL FRAME BEING
 ATTACHED TO THE EXISTING ELEVATOR SHAFT, BUT THERE IS
 NO INFORMATION AS TO HOW THE MANUFACTURED BUILDING IS
 TRANSFERRING THE LOADS TO THE STRUCTURAL STEEL
 FRAMEWORK, PART OF THE MAIN WIND FORCE RESISTING
 SYSTEM. 2010 1609.4.1.
  
 4) 3RD REQUEST. SHEET C4 THE ELEVATIONS INDICATE WHAT
 APPEARS TO BE TRIM ON THE CONCEALMENT SCREENS AND
 ARCHITECTURAL DECOR TO MATCH THE BUILDING ON THE
 MODULAR BUILDING, PLEASE PROVIDE COMPLIANCE WITH:
  
 2010 FBC-B 1406.2.2 TYPE I, II, III AND IV
 CONSTRUCTION.
 ON BUILDINGS OF TYPE I, II, III AND IV CONSTRUCTION,
 EXTERIOR WALL COVERINGS SHALL BE PERMITTED TO BE
 CONSTRUCTED OF WOOD IN ACCORDANCE WITH SECTION 1405.5,
 OR OTHER EQUIVALENT COMBUSTIBLE MATERIAL, COMPLYING
 WITH THE FOLLOWING LIMITATIONS: (2.) COMBUSTIBLE
 ARCHITECTURAL TRIM SHALL BE LIMITED TO 40 FEET (12 192
 MM) IN HEIGHT ABOVE GRADE.
  
 SUBMITTED REPORTS:STEALTHSKIN V (FR-ESSV) CONSEALMENT
 PANEL- OK MEETS THE REQUIREMENT
 GLASTEEL FIRE RETARDANT LINER PANEL -OK MEETS THE
 REQUIREMENT
 3" HARDCOAT FOAM, 60 MIL THICKNESS FAILS TO MEET THE
 REQUIREMENT OF E84 COMPOSITE MATERIALS FLAME SPREAD NOT
 GREATER THAN 50, TESTED THE FLAME SPREAD
 WAS 140.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved