Date |
Text |
2013-07-31 09:15:33 | BUILDING PLAN REVIEW |
| PERMIT: 13070610 |
| ADD: 720 S SAPODILLA AV- ROOFTOP |
| CONT: HAYDEN PROFESSIONAL SERVICES |
| TEL: (772)781-1512 |
| 2010 FLORIDA BUILDING CODE W |
| * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: 7/31/2012 |
| ACTION: DENIED |
| |
| 1) PLANS BEING SUBMITTED FOR CITY REVIEW REQUIRES CITY |
| PLACE STAMP OF REVIEW AND APPROVAL. |
| |
| 2) THE PLANS INDICATE THE INSTALATION OF A MODULAR |
| BUILDING BUT NO PLANS WERE SUBMITTED. IF THIS IS A |
| STATE APPROVED MODULAR BUILDING PLANS STILL NEED TO BE |
| SUBMITTED WITH THE STATE APPROVAL. NOTE THERE ARE |
| LIMITATIONS ON STATE APPROVED PLANS REVIEW THE DESIGN |
| PERAMTERS TO SEE IF IT WAS APPROVED WITH THE ASSOCAITED |
| PRESSURES BEING PLACED AT THIS ELEVATION. 107.2.1.3 |
| ADDITIONAL INFORMATION IS REQUIRED. |
| |
| 3) SHEET S2 DETAIL # 5 INDICATES A SPECIAL PLATE DETAIL |
| OF THE STEEL FRAME BEING ATTACHED TO THE EXISTING |
| ELEVATOR SHAFT, BUT THERE IS NO INFORMATION AS TO HOW |
| THE MANUFACTURED BUILDING IS TRANSFERRING THE LOADS TO |
| THE STRUCTURAL STEEL FRAMEWORK, PART OF THE MAIN WIND |
| FORCE RESISTING SYSTEM. 2010 1609.4.1. |
| |
| 4) SHEET C4 THE ELEVATIONS INDICATE WHAT APPEARS TO BE |
| TRIM ON THE CONCEALMENT SCREENS AND ARCHITECTURAL DECOR |
| TO MATCH THE BUILDING ON THE MODULAR BUILDING, PLEASE |
| PROVIDE COMPLIANCE WITH: |
| |
| 2010 FBC-B 1406.2.2 TYPE I, II, III AND IV |
| CONSTRUCTION. |
| ON BUILDINGS OF TYPE I, II, III AND IV CONSTRUCTION, |
| EXTERIOR WALL COVERINGS SHALL BE PERMITTED TO BE |
| CONSTRUCTED OF WOOD IN ACCORDANCE WITH SECTION 1405.5, |
| OR OTHER EQUIVALENT COMBUSTIBLE MATERIAL, COMPLYING |
| WITH THE FOLLOWING LIMITATIONS: |
| (2.) COMBUSTIBLE ARCHITECTURAL TRIM SHALL BE LIMITED TO |
| 40 FEET (12 192 MM) IN HEIGHT ABOVE GRADE. |
| |
| A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A |
| RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| THIS REVIEW. |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| CONSTRUCTION SERVICES HOME PAGE |
| HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| |
| PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| |
| MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| |