2013-05-28 10:19:28FBC 2010 EXISTING BUILDING CODE
 FBC 2010 ACCESSIBILITY CODE
 FBC 2010 PLUMBING REVIEW #1
 DENIED:
  
 1. SHEET A 1 SHOWS RECONFIGURED RESTROOMS AND A NEW
 HI/LO DRINKING FOUNTAIN. A 2 SHOWS NEW LOUNGE SINK AND
 DRINKING FOUNTAIN. A3 SHOWS RECONFIGURED RESTROOMS. NO
 PLUMBING PLANS WERE INCLUDED WITH THIS SET OF DRAWINGS.
 FBC 2010 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR
 BUILDINGS. 107.3.5.1.3 PLUMBING:
 1. MINIMUM PLUMBING FACILITIES
 2. FIXTURE REQUIREMENTS
 3. WATER SUPPLY PIPING
 4. SANITARY DRAINAGE
 5. WATER HEATERS
 6. VENTS
 13. PLUMBING RISER
  
 2. FBC PLUMBING TABLE 403.1
 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES:
 A-2 RESTAURANTS - ONE SERVICE SINK IS REQUIRED.
  
 REVIEW BY
 LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 PHONE # 805-6692
 EMAIL [email protected]
 FAX # 805-6676
  