Plan Review Stops For Permit 17010385 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2017-08-16 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-08-16 |
Time |
14:44 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-08-16 |
Time |
14:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2017-05-31 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-05-31 |
Time |
08:28 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2017-05-31 08:28:29 | BUILDING PROVISO: | | PLUNGE POOL SERIES DESIGN & INSTALALLATION GUIDE & | | THERAPEUTIC PLUNGE POOLS | | A COPY OF THESE MANUALS SHALL BE ONSITE FOR ALL | | BUILDING AND PLUMBING INSPECTIONS. | | 1/30/2017 BUILDING PLAN REVIEW J. WITMER |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2017-01-30 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-01-30 |
Time |
08:33 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-01-30 |
Time |
07:45 |
Sent To |
|
|
Notes |
2017-01-30 08:33:15 | BUILDING PROVISO: | | PLUNGE POOL SERIES DESIGN & INSTALALLATION GUIDE & | | THERAPEUTIC PLUNGE POOLS | | A COPY OF THESE MANUALS SHALL BE ONSITE FOR ALL | | BUILDING AND PLUMBING INSPECTIONS. | | 1/30/2017 BUILDING PLAN REVIEW J. WITMER |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2017-01-31 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2017-01-31 |
Time |
08:26 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2017-01-31 |
Time |
08:26 |
Sent To |
|
|
Notes |
2017-01-31 08:26:47 | PROVISO: PLEASE PROVIDE SPECS ONSITE FOR INSPECTION | | | | V. PEREZ | | *6717 |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
N |
Date |
2017-08-15 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2017-08-15 |
Time |
09:50 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2017-08-15 |
Time |
09:50 |
Sent To |
|
|
Notes |
2017-08-15 09:51:10 | THERE ARE NO GAS HEATERS ASSOCIATED WITH THESE THERAPY | | POOLS. TKL. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2017-01-25 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2017-01-25 |
Time |
10:20 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2017-01-25 |
Time |
10:19 |
Sent To |
|
|
Notes |
2017-01-25 10:21:44 | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | THIS TIME. A GAS PERMIT IS REQUIRED FOR A CONTRACTOR TO | | PERFORM THE RELATED WORK. PROVIDE COMPLETE PLANS THAT | | REFLECT THE ENTIRE SCOPE OF GAS WORK TO BE DONE. WPB | | AMEND. TO FBC SEC.107.2.1. | | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL | | GAS SEC. 301.3. | | | | A SEPARATE PERMIT IS REQUIRED FOR THE GAS INSTALLATION. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2017-08-16 |
Time |
|
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2017-08-04 |
Time |
12:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-06-20 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2017-06-20 |
Time |
12:48 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2017-05-22 |
Time |
07:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-02-03 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2017-02-03 |
Time |
15:43 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2017-01-18 |
Time |
16:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2017-08-15 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-08-15 |
Time |
10:58 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-08-14 |
Time |
17:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-05-25 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-05-25 |
Time |
13:00 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-05-25 |
Time |
13:00 |
Sent To |
|
|
Notes |
2017-05-25 13:06:56 | 1ST REVIEW FBC-2014 MECHANICAL | | PERMIT #17010385 | | 5/25/17 | | | | RESULTS: DENIED. | | | | 1) THE MECHANICAL PIT FOR THE HYDROWORX POOL REQUIRES | | VENTILATION PER THE SUBMITTED DESIGN AND INSTALLATION | | GUIDE (PAGE 6), AND SECTION 13 1720 OF THE PROJECT | | SPECIFICATIONS (PAGE 4, ITEM 31). PLEASE PROVIDE | | DETAILED DRAWINGS, VENTILATION CALCULATIONS, AND | | EQUIPMENT SCHEDULES AND SPECIFICATIONS. | | | | 2) PROVIDE EQUIPMENT SCHEDULES FOR THE CHILLERS | | INDICATING THE MAKES AND MODELS OF THE UNITS, THE | | COOLING CAPCITIES, THE REFRIGERANT CLASSIFICATION AND | | QUANTITIES. | | | | 3) SHOW THE CHILLED WATER PIPING RUNS AND PROVIDE | | DETAILS- TYPE AND SIZES OF CHILLED WATER PIPING, PIPE | | INSULATION TYPE AND THICKNESS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2017-08-15 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2017-08-15 |
Time |
09:44 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2017-08-14 |
Time |
05:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2017-06-01 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2017-06-01 |
Time |
07:45 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2017-05-31 |
Time |
15:09 |
Sent To |
|
|
Notes |
2017-05-31 15:13:43 | 1) SHT.A2.613 & SHT. RP2.0 SHOW TWO WATER SUPPLIED | | CHILLERS IN THE EQUIPMENT PIT. THE WATER SUPPLY TO THE | | CHILLERS SHALL BE EQUIPPED WITH A BACKFLOW PREVENTER | | PER THE 2014 FBC- PLUMBING SEC. 608.3. | | 2) SUBMIT A POOL PIPING PLAN VIEW THAT CLEARLY REFLECTS | | THE LOCATION OF THE MAIN DRAINS, SKIMMERS AND RETURNS | | FOR EACH PLUNGE POOL. WPB AMEND. TO FBC SEC. 107.2.1. | | 3) PROVIDE THE TURNOVER RATE FOR EACH SPA ON THE PLANS. | | THE TURNOVER RATE FOR EACH SPA SHALL COMPLY WITH 2014 | | FBC-BUILDING SEC.454.1.8.8. | | 4) AUTOMATED OXIDATION REDUCTION POTENTIAL (ORP) AND PH | | CONTROLLERS WITH SENSING PROBES SHALL BE INSTALLED ON | | SPA POOLS TO ASSIST IN MAINTAINING PROPER DISINFECTION | | AND PH LEVELS. 2014 FBC-BUILDING SEC.454.1.8.12. | | 5) THERAPY OR JET PUMPS SHALL TAKE SUCTION FROM THE | | COLLECTOR TANK. 2014 FBC-BUILDING SEC. 454.1.8.6.2, | | 6) PROVIDE DETAILS FOR MAKEUP WATER. THE MAKEUP WATER | | LINE SHALL BE PROTECTED AGAINST BACKFLOW PER 2014 | | FBC-PLUMBING SEC. 608.1. | | 7) A FIXED THERMOMETER SHALL BE MOUNTED IN THE POOL | | RECIRCULATION DOWNSTREAM FROM THE HEATER | | OUTLET.THERMOMETERS MOUNTED ON HEATER OUTLETS DO NOT | | MEET THIS REQUIREMENT. 2014 FBC-BUILDING | | SECS.454.1.6.5.14, 454.1.8.1. | | 8) THE FLOW VELOCITY IN SUCTION PIPING SHALL NOT EXCEED | | 6 FT. PER SECOND. THE MAIN DRAIN SPECS SHOW 6.42 FPS. | | CLARIFY. 2014 FBC SEC. 454.1.6.5.8. | | 9) PAGE 3 - UTILITIES SECTION OF THE HYDROWORX DESIGN | | GUIDE SPECIFIES THAT A MINIMUM 2 INCH WATER SUPPLY LINE | | WITH ANTI-SIPHON DEVICE BE CONNECTED TO THE | | RECIRCULATION RETURN LINE, A 3/4" DIAMETER HOSE BIBB | | WITH ANT-SIPHON IN THE POOLROOM AND A 1- 1/2 INCH OR 2 | | INCH DIAMETER BUILDING LOOP LINE TO AND FROM THE WATER | | COOLED CHILLER. SUPPLY THIS INFORMATION/DETAIL FOR | | REVIEW. SUBMIT PLUMBING SCHEMATIC FROM HYDROWORX. | | 10) INDICATE WHAT MEANS IS PROVIDED FOR DRAINING THE | | SPAS. | | 11) PAGE 7 OF THE HYDROWORX DESIGN GUIDE RECOMMENDS | | INSULATION OF THE CHILLED WATER. PROVIDE DETAIL ON | | THICKNES OF INSULATION. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2017-01-25 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2017-01-25 |
Time |
08:57 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2017-01-25 |
Time |
06:08 |
Sent To |
|
|
Notes |
2017-01-25 09:01:08 | 1) SUBMIT COMPLETE POOL PIPING DRAWINGS FOR ALL OF THE | | HYDROWORX THERAPY POOLS. WPB AMEND. TO FBC SEC.107.2.1, | | DRAWINGS SHALL BE SIGNED AND SEALED BY AN ENGINEER | | REGISTERED IN THE STATE OF FLORIDA.WPB AMEND. TO FBC | | SEC. 107.1. | | 2) A PERMIT APPLICATION SHALL BE SUBMITTED BY A POOL | | CONTRACTOR CURRENTLY LICENSED IN THE STATE OF FLORIDA. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2017-08-16 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2017-08-16 |
Time |
16:06 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2017-08-16 |
Time |
16:06 |
Sent To |
|
|
Notes |
2017-08-16 14:45:32 | 8/16/2017 CHECKED ARCHITECTURAL AND STRUCTURAL SHEETS. | | OK/ JW. | 2017-05-25 15:34:51 | NO MECHANICAL PLAN SHEETS TO CHECK | | CCOLE- 5/25/17 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2017-02-03 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2017-02-03 |
Time |
15:42 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2017-02-03 |
Time |
15:42 |
Sent To |
|
|
Notes |
|
|